![coleman hot tub error codes coleman hot tub error codes](https://i3.ytimg.com/vi/Di6t1YFmwqA/hqdefault.jpg)
While in this mode your hot tub will only heat while it filters. If you wish to see the temp either switch the spa to standard mode or turn Jets 1 on for 2-4 min. In Economy or Sleep mode, the pump may be off for hours outside a filter cycle. Temperature not current in Economy or Sleep mode. After 2-4 min of the pump running the temp will be displayed. There is no action required during this time, just wait to hit any buttons till this message goes away. The Priming cycle will last from 4-7 min. This message is displayed when your hot tub is first powered on. (Displays on the fifth occurrence of the HFL message within 24 hours.) Heater is shut down, but other spa functions continue to run. If the problem continues make sure circulation pump is moving water. If error message goes away you have dirty filters. Run a hot tub temporarily with filters out of the hot tub and see if the problem continues. While cleaning your filter make sure there is no debris in your hot tub that will get sucked down into your pump. This means that there is a flow issue through your heater. This could indicate a flow problem.įor the error messages of HFL, LF, Dr, or DRY.
#Coleman hot tub error codes Pc#
Find replacement sensor, or Find replacement PC board.Ī substantial difference between the temperature sensors was detected. If you still have a problemyou either have bad sensor or PC board. If the problem comes back, try and unplug the sensors and switch where they are plugged in. Shut the spa off for 20 min to reset the power. If the display shows only this message(blinking), the spa is shut down. If this alternating with the temp, it may just be a temporary condition.
![coleman hot tub error codes coleman hot tub error codes](https://i5.walmartimages.com/asr/ab6c148d-e937-4dde-920a-178f0cf66f61.c2889ea93e88af7f1f6cf1508418ed55.jpeg)
If the problem stays SnA, then you have a bad PC board. If the problem switches to SnB, then you have a bad sensor.
![coleman hot tub error codes coleman hot tub error codes](https://i.ytimg.com/vi/cijwl0guEdI/maxresdefault.jpg)
The sensor that is plugged into the Sensor “A” jack is not working. The heater will turn on once the water is to 45°. If spa doesn’t reset there is an issue with sensors or PC board. Remove spa cover and let the water cool down. One of the sensors has detected that the spa water is 110☏. If the spa doesn’t reset there is an issue with sensors onPC board. After the water has cooled, push any button to reset. One of the sensors detected 118☏ at the heater. Try unplugging topside and plugging into another port. Power has been cut off to the spa.Ĭheck your breaker and turn back on, if off.